The Problem BLADE Solves

Not every laboratory runs the same sample twice.

Batch digestion systems like the MARS 6 require all samples in a run to share the same method — the same acid combination, temperature, pressure profile and hold time. This works well for batches of similar samples. It works poorly when a laboratory receives varied matrices every day, as commercial testing laboratories do. BLADE processes each sample individually: a soil, a food product, a pharmaceutical tablet and a plastic can all be loaded into the same sequence, each receiving its own acid chemistry and temperature profile.

Why “World’s Fastest” is the Right Frame

A 40-sample rack in about three hours — with individual methods per sample.

A 5-minute sequential digest means a 40-sample rack completes in about three hours — comparable to a batch system run, but with the flexibility of sequential individual methods. For the first time, speed and flexibility are not a trade-off. CEM has publicly demonstrated BLADE to Agilent teams and published installations at Eurofins; both organisations have a significant South African presence.

The Core Technology

Single Mode Cavity and vortexing.

CEM combined advanced vortexing with Single Mode Cavity™ (SMC) technology to deliver the highest watt-density available, achieving clear digestions in a fraction of the time of traditional microwave digestion systems. A single-mode cavity concentrates the microwave standing wave at one point rather than distributing it across a large multimode chamber, producing very high energy density. Vortexing agitates the sample during the run, improving heat and mass transfer so the acid reaches all of the sample rather than only the surface of a settled bed.

The Four Pillars

CEM's own framing for what makes BLADE different.

Digestion in minutes. SMC technology plus vortexing delivers the highest watt-density and clear digestions in a fraction of the time of traditional systems.

Add sample and acid, snap on a cap, load into the autosampler. No vessel assembly — a departure from multi-component screw-assembled batch vessels. Processing, including cool-down, is automatic.

Barcode scanning follows a sample from balance to analysis. BLADE is the only microwave digestion system that automatically loads and unloads vessels from the cavity, with CFR-compliant documentation for every sample.

Samples and acids — including HNO₃, HCl and HF — can be mixed and matched in one run. A high-definition built-in camera allows the digestion to be watched in real time.

Compliance & Traceability

Audit evidence produced as a by-product of running the work.

BLADE handles HNO₃, HCl and HF, and permits mixing different acids across samples within the same run — relevant to South African mining laboratories processing both geological (HF) and non-geological samples in one continuous run.

Who Needs BLADE

Mixed-matrix, daily-intake laboratories.

Receiving mixed matrices daily — the primary use case.

Tablets, excipients and packaging requiring different digestion protocols.

Grain, oil and packaging in the same run.

Flexibility to develop new methods without committing an entire batch run.

Compliance Standards Supported

Documentation built for regulated and accredited environments.

Industries Served

Where BLADE's mixed-matrix flexibility is put to work.

See BLADE handle your mixed-matrix samples

Ask our applications team whether BLADE or MARS 6 fits your laboratory's sample mix.

Traditional batch vesselBLADE vessel
AssemblyMulti-component; screw assembly per vesselSnap-on cap; no assembly
MaterialPTFE/TFM fluoropolymer (typically)High-purity quartz
CleaningDisassemble, wash, dry, reassembleEasy-clean single piece
Cool-downManual removal and waitAutomatic, included in the run
Handling per sampleSeveral minutes of analyst timeLoad and walk away
MARS 6BLADE
FormatBatch — all samples in one runSequential — one sample at a time
ThroughputUp to 40 samples simultaneously~5 minutes per sample
Method per sampleSame method for all samples in the runIndividual method per sample
Best forHigh volumes of similar matrixMixed matrices; varied sample types
AutomationManual loading; runs unattendedAutomated sequential; fully unattended
Milestone's critique of batch digestionHow BLADE addresses it
Pre-cleaning acid blank cyclesSingle-piece quartz vessel, easy-clean
Labour-intensive assembly/disassemblySnap-on cap, no assembly
Digestate transfer requirementsNot eliminated — digestate is still transferred for analysis
Vessel degradation costsQuartz vessel; degradation profile differs from PTFE/TFM
All samples must share weight, matrix and acidIndividual method per sample; mixed acids in one run