Why Soxhlet Needs Replacing

A nineteenth-century technique, still in daily use.

Soxhlet extraction runs 6–24 hours, consuming 150–300 mL of hazardous solvent per sample, generating waste requiring licensed disposal and exposing operators to vapours. The economics of solvent disposal alone often justify replacement: MAD's own experience puts the solvent used across 500 Soxhlet extractions a year at roughly the same quantity consumed by just 32 extractions run on EDGE.

How EDGE Works

Sealed vessel, focused microwave energy, minutes not hours.

Sample and solvent are sealed in a vessel (Q-Cup / Q-Disc) and heated by focused microwave energy above the solvent's atmospheric boiling point. Higher temperature raises analyte solubility and diffusion rate; extractions that take hours at reflux complete in minutes. The Q-Cup/Q-Disc filtration design removes the separate filtration step traditional accelerated solvent extraction requires.

For non-polar solvents — microwave-transparent and would not heat on their own — EDGE uses Carboflon® stir bars that absorb microwave energy and transfer heat to the solvent. Existing solvent chemistry does not need to change.

Applications

One extraction platform, many matrices.

Total fat/oil analysis, FAME determinations for food, feed and biodiesel.

EPA Method 1633/1633A, 40 PFAS compounds across environmental matrices.

Antioxidants, plasticisers, stabilisers, slip and anti-static agents.

Extractables and leachables from packaging.

EPA 3546 and equivalent methods for semivolatile and nonvolatile organics.

Solvent Reduction

Up to 95% less solvent than Soxhlet.

Relevant Standard Methods

The methods this system is designed to satisfy.

Industries Served

Where EDGE replaces Soxhlet extraction.

Related Products

Digestion of the same sample types where required.

NMR fat analysis — an alternative to solvent extraction for fat content specifically.

Building PFAS or fat extraction capability?

SoxhletEDGE
Time per sample6–24 hours~5 minutes
Solvent per sample150–300 mLUp to 95% less
Filtration stepSeparate step requiredBuilt into Q-Cup/Q-Disc design
Operator vapour exposureHigher — open reflux over hoursLower — sealed vessel
Waste disposalLarger volume, licensed disposalReduced volume
Existing solvent chemistryUnchanged — no method redevelopment for solvent selection
Bench time & footprintOccupied for entire runMinutes, sequential automated
FAQs

Questions we are asked about the EDGE.