Autosamplers & Automation — product photograph
Autosamplers & Automation
Why an Autosampler Is Not Just Automation

Loading a rack at 17:00 is the least of it.

The simplest benefit of an autosampler is unattended operation — loading a rack and collecting results in the morning. The more important benefits are analytical: carryover, contamination and settling problems that no amount of operator care can fully solve by hand, solved instead by the autosampler's own design.

Product Range

A configuration for every sample introduction problem.

ASX-260, ASX-520, ASX-560 — general purpose, reliable, wide ICP/ICP-MS compatibility.

ASX-110FR (metal-free, flowing rinse, from 500 µL), ASX-112FR.

ASX-1400 (with stirring paddles), ASX-1600.

XLR-8, XLR-860 — up to 720 sample positions.

The Case for ASX-1400 / ASX-1600

A settled sample gives a meaningless result.

Used oil wear-metal analysis predicts mechanical failure in engines, gearboxes and hydraulic systems before it happens — by tracking iron, chromium, copper, lead, aluminium and silicon in lubricating oil. South African mining and heavy transport run extensive oil-analysis programmes on haul trucks, draglines, mills and locomotives, because an unplanned gearbox failure costs orders of magnitude more than the monitoring programme.

The problem: used oil samples contain suspended wear metal debris that settles between sampling and analysis. The ASX-1400 and ASX-1600 homogenise each sample with a variable-speed stirring paddle immediately before aspiration, with an independent rinse for both probe and stirrer and a drip cup preventing cross-contamination — a purpose-built solution for a large South African market segment.

The ASXpress Plus Argument

Half the run isn't measurement.

Roughly half of an ICP-MS run's clock time is not measurement time — it is the probe travelling, rinsing, and the sample washing into and out of the spray chamber. ASXpress Plus pre-loads the next sample into a valve loop while the current one is being measured, then switches it in instantly, cutting this dead time significantly. For a commercial laboratory billing per sample, this is a direct increase in revenue capacity from a modest accessory.

Industries Served

Wherever an ICP-OES or ICP-MS runs, an autosampler runs with it.

Match the autosampler to your application

Flowing rinse, stirring, extended rack or rapid introduction — our applications team will help you configure the right model.

ProblemSolution in the autosamplerProduct
Carryover between high-concentration samplesContinuous flowing rinse stationsASX-110FR, mercury systems
Contamination at ICP-MS trace levelsMetal-free, high-purity polymer construction; PFA sample path; enclosure hoodASX-110FR, ENC-500
Settling of particulate in oil/wear-metals samplesAutomatic stirring immediately before aspirationASX-1400, ASX-1600
Cross-contamination from probe dripsDrip cup that travels with the probeASX-1400/1600
Dead time between samplesPre-loaded sample loop, instant switchingASXpress Plus
Samples too concentrated for calibration rangeAutomated in-line dilutionADX-500, SDS-550
Very small sample volumesMicro-autosamplers from 500 µLASX-110FR, MVX-7100 µL
Very large sample loadsExtended rack configurationsXLR-8, XLR-860
Model(s)CategoryKey differentiator
ASX-260, ASX-520, ASX-560StandardGeneral-purpose, wide ICP/ICP-MS compatibility; ASX-260/ASX-520 also available with QuickTrace mercury systems
ASX-110FRUltraTraceMetal-free, high-purity polymer path with continuous flowing rinse; sample volumes from 500 µL
ASX-112FRUltraTraceFlowing-rinse UltraTrace configuration
ASX-1400Wear metals / oilVariable-speed stirring paddle homogenises settled particulate immediately before aspiration
ASX-1600Wear metals / oilStirring configuration with independent probe/stirrer rinse and drip cup
XLR-8, XLR-860Extended rackUp to 720 sample positions for very large sample loads
ASXpress PlusRapid introductionPre-loaded sample loop cuts dead time between measurements
ADX-500, SDS-550Auto-dilutionAutomated in-line dilution for over-range samples
MVX-7100 µLMicro-volume500 µL to 15 mL sample volumes
ENC-500Anti-contaminationEnclosure hood for trace-level contamination control
APS-1650Multi-positionMulti-position autosampler configuration